2014-04-15/00529103
Data Sheet 705000 Page 4/10
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone: +49 661 6003-0
Fax: +49 661 6003-607
Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax: +44 1279 635262
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: 315-437-5866
1-800-554-5866
Fax: 315-437-5860
Internet: www.jumousa.com
Base units
The base unit, up to 30 input/output modules, and up to 30 router modules can be used to build a compact and economic central or decentral
measuring, control, and automation system (visualization and operation either with the multifunction panel or the plant visualization software
JUMO SVS3000).
The base units contain the process image of the application. Furthermore, all configuration and parameter data of the system are stored in these
modules (except for the multifunction panel). As a result, individual input/output modules can be replaced with Plug and Play.
All base units operate at a voltage supply of DC 24 V.
The setup program or the multifunction panel can be used to comfortably configure and parameterize the base units.
LEDs are used to indicate the voltage supply as well as the operating status of a module and of the interfaces.
Central processing unit
Additional base units in preparation.
The central processing unit is the basis for the maximum exten-
sion of the system
Nine program generators (option)
64 limit values are monitored
An integrated PLC acc. to IEC 61 131-3 (option)
Math and logic function (option) for all connected multichannel
controller modules
Two interfaces for field bus applications; optional:
- RS232, Modbus RTU as master or slave
- RS422/485 Modbus RTU as master or slave
- PROFIBUS-DP as slave (as of system version 02)
One USB device interface (setup)
System bus connection at the front (Bus Out)
A LAN interface (Ethernet) for HTTP and Modbus/TCP as master
and slave
Integrated web server
E-mail transmission
The central processing unit operates at a voltage supply of
DC 24 V and supplies the connected input/output modules
Dimensions (W x H x D): 135 mm x 101 mm x 67.1 mm
(without connection elements)
For further information: Refer to data sheet 705001